50 Mt. (164 Ft.) Italian
Luxury Yacht
.
The final specification, complete with every detail of the
construction and relevant drawings that constitute integrating
part of the project, shall be delivered only upon signature of
the shipbuilding contract between the owner and the builder
Italian Blue.
Aldo Viani & Luciano Gobbi Benelli Associates shall take
care of all aspects concerning hull shape, hydrodynamics,
structural scantlings, choice of materials, drawings and general
naval architecture.
As far as interior layout and decoration are concerned the
designer shall be Mr. Terence Disdale of TERENCE DISDALE DESIGN.
The Builder shall be Italian Blue Ltd.
The vessel shall be conceived with four continuous living and
sheltered decks, an exterior sun deck of ample dimensions and a
longitudinal technical tunnel in the double bottom. The Vessel
is divided in five watertight compartment through four
watertight bulkheads which extend from the top of the double
bottom to the main deck.
As shown on the General Arrangement Plan, the partition of the
Vessel shall be as follows:
| Main dimensions |
Meters |
Feet |
| Length overall |
49,95 |
164,00 |
| Length at water line (About) |
45,00 |
137,00 |
| Moulded breadth |
8,80 |
29,00 |
| Maximum breadth |
9,40 |
31,00 |
| Moulded depth
(subject to Owner requirements) |
2,90 |
9,50 |
| Top Height (from B.L) |
13,60 |
44,60 |
| Maximum draft under keel |
3,00 |
9,85 |
|
|
Consumable volumes on board
are the followings:
.
|
| Fuel oil |
m3 |
95 |
| Lube oil |
m3 |
2 |
| Dirty oil |
m3 |
1 |
| Fresh water |
m3 |
8 |
| Ballast water |
m3 |
0 |
| Fresh water maker
capacity/day |
Tons |
10 |
| Total dead weight in total is of |
Tons |
106 |
| Trial deadweight
(App.) |
Tons |
38 |
| Gross tonnage
(preliminary) |
Tons |
95 |
|
|
| . |
|
Classification
- ABS - Lloyd's Register and lull MCA
Main Engines
- N. 2 CATERPILLAR DITA/SWAC 3512B of 1340 Kw each.
Main and Emergency Generators
- N. 2 Main Diesel Gensets (Alaska Diesel, Caterpillar, Deutz or Mann), each silenced in sound proof box, of 200 KW each at 380V, 50 Hz, 3 phases, 1500 rpm.
- N. 1 Emergency Diesel Genset (Alaska Diesel or Volvo
Penta) of 100 KW at 1500 rpm, 380V, 3 phases (Manufacturer and type to be determined with the owner).
Air conditioning: Cruise Aire or Condaria
|
|
. |